The above unit price does not include the cabinet and battery.
Warranty: 36 months
– 3-phase input and 3-phase output UPS with double conversion technology and advanced processors, the 3C3 PRO series is ideal for backup storage for industrial equipment, information technology, and more.
– Effective protection in industrial environments
– Easy installation, operation, and maintenance
– High efficiency
– LCD screen provides all information related to power source and UPS operation
– Expandable and multi-layered protection using the same battery system
– Equipped with multiple interface connections allowing remote management and communication with external circuits, creating a comprehensive power management solution
– On-site repair, maintenance, and component replacement services at reasonable costs. Fast troubleshooting response is a top requirement when equipping large capacity UPS, and we are the unit that always meets all these requirements.
DETAILED TECHNICAL SPECIFICATIONS
| INPUT | |
|---|---|
| Rated Voltage | 380VAC (L-L) / 220 (L-N) |
| Voltage Range | 201 ~ 478VAC (L-L) / 116 ~ 276VAC (L-N) |
| Phases | 3-phase (Star type – 4 wires + ground) |
| Rated Frequency | 42 ~ 72 Hz |
| Power Factor | ≥ 0.99 |
| Generator Compatibility | Yes |
| OUTPUT | |
| Power | 120 KVA / 108 KW |
| Voltage | 380VAC (L-L) / 220 (L-N) ±1% |
| Phases | 3-phase (Star type – 4 wires + ground) |
| Waveform | Pure sine wave in all grid states and independent of the remaining capacity of the battery source. |
| Frequency | Synchronized with input 50/60Hz ±4Hz or 50/60Hz ±0.05Hz (battery mode) |
| Load Connection Type | 3-phase (Star type – 4 wires + ground) |
| Efficiency | 94% (AC and battery mode) >98% (ECO mode) |
| Overload Capacity | ≥ 110% ~ 125% for 10 minutes, 125% ~ 150% for 1 minute |
| Output Connection | Terminal block |
| BYPASS MODE | |
| Automatic Switch to Bypass | Overload, UPS fault |
| BATTERY | |
| Battery Type | 12 VDC, sealed, maintenance-free |
| Backup Time | Depends on the capacity of the external battery – Customer can choose according to needs and cost |
| Battery Recharge Time | Depends on the capacity of the external battery |
| INTERFACE | |
| Control Panel | LCD screen and function keys |
| Status Indicator LEDs | AC mode, battery mode, bypass mode, warning |
| Communication Ports | RS232, AS400, EPO, smart slot |
| Management Software | Winpower energy management software with auto system shutdown; compatible with Windows, Linux, Unix, Sun |
| Switching Time | 0 ms |
| Emergency Power Off Function (EPO) | Yes |
| Parallel Redundancy Function (N+X) | Allows up to 4 units in parallel operation for multi-layer redundancy (N+X), capacity expansion, and balanced load sharing. |
| OPERATING ENVIRONMENT | |
| Operating Temperature | 0 ~ 40°C |
| Operating Humidity | 20% ~ 90%, non-condensing |
| Cooling System | Air convection fans |
| STANDARDS | |
| Noise Level | 62 dB (excluding alarm) |
| Electromagnetic Field (EMS) | IEC 61000-4-2 Level 3 (ESD) |
| IEC 61000-4-3 Level 3 (RS) | |
| IEC 61000-4-4 Level 4 (EFT) | |
| IEC 61000-4-5 Level 4 (Surge) | |
| Conducted and Radiated EMI | IEC62040-2:2005 / EN50091-2:1996, for input current ≥ 25A |
| DIMENSIONS / WEIGHT | |
| Dimensions (W x D x H) (mm) | 600 x 800 x 1876 |
| Net Weight (kg) | 311 |