The above unit price does not include the cabinet and batteries.
Warranty: 36 months
– 3-phase input, 3-phase output UPS with double conversion technology and advanced processor. The 3C3 PRO series is ideal for industrial equipment backup and information technology applications…
– Effective protection in industrial environments
– Easy installation, operation, and maintenance
– High efficiency
– LCD screen provides all information related to power and UPS operation
– Scalable and multi-level protection using a shared battery system
– Equipped with several peripheral connections for remote management and external circuit communication, providing a comprehensive power management solution
– On-site repair, maintenance, and parts replacement services at reasonable cost. Fast response time in troubleshooting is a top requirement for high-capacity UPS systems, and we always meet all these demands.
DETAILED TECHNICAL SPECIFICATIONS
| INPUT | |
|---|---|
| Nominal Voltage | 380VAC (L-L) / 220 (L-N) |
| Voltage Range | 201 ~ 478VAC (L-L) / 116 ~ 276VAC (L-N) |
| Number of Phases | 3 phases (Star configuration – 4 wires + ground) |
| Nominal Frequency | 42 ~ 72 Hz |
| Power Factor | ≥ 0.99 |
| Generator Compatibility | Yes |
| OUTPUT | |
| Power Capacity | 160 KVA / 144 KW |
| Voltage | 380VAC (L-L) / 220 (L-N) ± 1% |
| Number of Phases | 3 phases (Star configuration – 4 wires + ground) |
| Waveform | True sine wave in all power conditions and regardless of remaining battery capacity. |
| Frequency | Synchronized with input 50/60Hz ± 4Hz or 50/60Hz ± 0.05Hz (battery mode) |
| Load Connection Type | 3 phases (Star configuration – 4 wires + ground) |
| Efficiency | 94% (Mains, battery mode) >98% (ECO mode) |
| Overload Capacity | ≥ 110% ~ 125% for 10 minutes, 125% ~ 150% for 1 minute |
| Output Connection | Terminal block |
| BYPASS MODE | |
| Automatic Transfer to Bypass Mode | Overload, UPS fault |
| BATTERY | |
| Battery Type | 12VDC, sealed, maintenance-free |
| Backup Time | Depends on external battery capacity – customer chooses according to needs and cost |
| Recharge Time | Depends on external battery capacity |
| INTERFACE | |
| Control Panel | LCD screen and control buttons |
| Status LEDs | Mains mode, battery mode, bypass mode, alarm |
| Communication Ports | RS232, AS400, EPO, intelligent slot |
| Management Software | Winpower energy management and auto shutdown software, compatible with Windows, Linux, Unix, Sun |
| Transfer Time | 0 ms |
| Emergency Power Off (EPO) Function | Yes |
| Parallel Redundancy N+X Function | Allows parallel connection of up to 4 units for multi-layer redundancy (N+X), power increase, and load sharing. |
| OPERATING ENVIRONMENT | |
| Operating Temperature | 0 ~ 40°C |
| Operating Humidity | 20% ~ 90%, non-condensing |
| Cooling System | Air convection cooling fan |
| STANDARDS | |
| Noise Level | 62 dB excluding alarm buzzer |
| Electromagnetic Field (EMS) | IEC 61000-4-2 Level 3 (ESD) |
| IEC 61000-4-3 Level 3 (RS) | |
| IEC 61000-4-4 Level 4 (EFT) | |
| IEC 61000-4-5 Level 4 (Surge) | |
| Conducted and Radiated EMI | IEC62040-2:2005 / EN50091-2:1996, with input current ≥ 25A |
| DIMENSIONS / WEIGHT | |
| Dimensions (W x D x H) (mm) | 600 x 830 x 1876 |
| Net Weight (kg) | 457 |
VN



Reviews